Awards Nomination 20+ Million Readerbase
Indexed In
  • Academic Journals Database
  • Genamics JournalSeek
  • Academic Keys
  • JournalTOCs
  • China National Knowledge Infrastructure (CNKI)
  • Scimago
  • Access to Global Online Research in Agriculture (AGORA)
  • Electronic Journals Library
  • RefSeek
  • Directory of Research Journal Indexing (DRJI)
  • Hamdard University
  • EBSCO A-Z
  • OCLC- WorldCat
  • SWB online catalog
  • Virtual Library of Biology (vifabio)
  • Publons
  • MIAR
  • University Grants Commission
  • Geneva Foundation for Medical Education and Research
  • Euro Pub
  • Google Scholar
Share This Page
Journal Flyer
Flyer image
Detection of various parasitic protozoa from raw water and water supplies: A PCR study
3rd World Congress and Expo on Applied Microbiology
November 07-09, 2016 Dubai, UAE

Eun-Young Jung, Hong-Ki Park, Dong-Jin Cha, Hyo-Sang Lim and Jin-Tak Choi

Busan Water Quality Institute, South Korea

Scientific Tracks Abstracts: J Microb Biochem Technol

Abstract:

Waterborne parasitic protozoa outbreaks are on an increase, although there are better surveillance and reporting systems in several countries. The most prevalent water borne parasitic infections producing diarrhea are cryptosporidiosis and giardiasis; the common waterborne parasitic protozoa that cause human infections are Toxoplasma gondii, Cyclospora, Microspora, Naegleria spp., etc. Pathogenic protozoa have a biologically different shape during their life cycle in the host. Although there are various methods available, detection of pathogenic protozoa is more difficult as compared to other methods. For monitoring of the protozoa in the water source system, we mainly conducted direct microscopic observations. In this study, 6 kinds of the waterborne parasitic protozoa were detected by the PCR method in samples collected from Nakdong River. The results of water quality in this investigation showed an average of total coliforms (TC) 40~4,900 MPN/100 mL and fecal coliforms 0~1,100 MPN/100 mL. The water quality during this survey showed an improvement when compared to results of the previous year (conducted during the same period), but the number of bacteria were temporarily increased due to turbidity caused by rainfall. Parasitic protozoa were not detected in any of the source water samples of the Busan metropolitan city. We confirmed the microbiological safety of drinking water produced by the treatment system. Thus, it is necessary to monitor the bacteriological load in water, so as to ensure the safety of water supplies. Further studies are required to compare the specificities and sensitivities of several methods to accurately detect parasitic protozoa.

Biography :

Eun-Young Jung has completed his PhD in Microbiology. He has been working in Busan Water Quality Institute in South Korea since 15 years.

Email: meetjung@korea.kr