The major step in thin-layer chromatography in which the real separation occurs is plate-development. In this step, a solvent system is introduced to the sample on the TLC layer in order to separate the mixture into individual substances. Separation can be achieved through various methods. Thin Layer Chromatography (TLC) is probably the most common method for the separation of polar lipids. Two dimensional TLC provides better resolution, while one dimensional TLC is frequently utilized for small scale preparative or rapid group separation activities. Phospholipid separations using silica gel G plates produced in chloroform, methanol, and water are helpful. A variety of solvent mixtures, including chloroform 28%, methanol 28% aqueous ammonia or chloroform, acetone, methanol acetic acid, water, have been used for TLC separations of polar lipids. These mixtures usually contain acetic acid or ammonia.

Vertical TLC plate is placed in a suitable TLC developing chamber so that the solvent wets the TLC layer below the starting line in this typical TLC development process. The solvent raises the sample mixture up the layer due to capillary forces. The plate is withdrawn from the chamber, the solvent front is marked with a pencil or spatula, and the plate is dried once the solvent front has reached the predetermined height (10-15 cm for TLC and 3-7 cm for HPTLC).

Horizontal TLC plate is placed horizontally inside the chamber when utilising this TLC developing technique, and the solvent is applied using a wick or capillary slit. The TLC plate's development can be done either from one or both sides. Two dimensional TLC sample is applied to a starting point in a corner of the TLC plate during the formation of two dimensions in TLC.

The plate is placed in a typical chamber and once developed from bottom to top. After drying, the plate is rotated 90 degrees and put in a new chamber with a different solvent before being developed once more. The first development's chromatogram track serves as the starting point for the second development.

The TLC plate moves through several cycles in this approach, drying between each cycle. Repeatedly moving across the layer, the solvent refocuses and distorts the spots, frequently resulting in circular forms or narrow bands. With this, resolution for compounds with Rf values under 0.5 is greatly improved. The same solvent or other solvents with variable degrees of polarity can be used to perform multiple developments over various separation distances.

AMD (Automated Multiple Development), which is based on a gradient solvent system, is an automated variation of multiple developments. Solvents with decreasing polarity are used and each additional development stage is carried out across a greater distance when it comes to silica gel TLC layers. Development is best done in specialized U-chambers with a pump supplying the solvent. The solvent is removed under vacuum after each cycle. Excellent resolution and sensitivity are provided by AMD, and each step can be preselected at will.

When a small amount of an analytic in radioactive form is added to the sample, radiochemical methods can be used to trace the presence of a specific analyte. This tracing procedure can be used in connection with chromatographic separations. On radiopharmaceuticals reconstituted from permitted cold kits, HPLC shouldn't be required. It is helpful to have methods at hand for attempting to solve the root of any abnormal patient scan. An HPLC approach for determining RCP is necessary for radiopharmaceuticals made for novel chemicals used for research.