Mass spectrometry is a powerful analytical technique for quantifying known substances, identifying unknown compounds in samples, and elucidating the structure and chemistry of various molecules. The complete process converts the sample into gaseous ions. It is characterized by mass-to-charge ratio (m/z) and relative abundance with or without fragmentation. This technique basically studies the effect of ionization energy on molecules. This depends on the chemical reaction in the gas phase where the sample molecules are consumed during the formation of ionic and neutral species.

Basic principles

A mass spectrometer produces multiple ions from the sample under investigation, separates them according to a specific massto- charge ratio (m/z), and records the relative abundance of each ion type. The first step in mass spectrometry of a compound is essentially the generation of gas phase ions in the compound by electron ionization. This molecular ion undergoes fragmentation. Each primary product ion derived from a molecular ion undergoes fragmentation in turn. Ions are separated by a mass spectrometer according to the mass-to-charge ratio and detected in proportion to their abundance. In this way, the mass spectrum of the molecule is created. The results are displayed in the form of a graph of ion abundance and mass-tocharge ratio. Ions provide information about the properties and structure of their precursor molecules. In the spectrum of a pure compound, if molecular ions are present, they are displayed at the highest value of m/z (followed by ions containing heavier isotopes), indicating the molecular weight of the compound.

Components

The equipment consists of three main components:

Ion source: It generates gaseous ions from the substance to be inspected.

Analyzer: Decomposes ions into characteristic mass components according to the mass-to-charge ratio.

Detector system: It detects ions and records the relative abundance of each degraded ion species.

In addition, a sample introduction system is required to send the sample under investigation to the ion source while maintaining the high vacuum requirements of the technology (~106-108 mm Hg). You also need a computer to control the equipment, retrieve and manipulate the data, and compare the spectrum to the reference library. With all of the above components, the mass spectrometer should always perform the following process:

Generates ions from a sample of the ionization source.

A mass spectrometer separates these ions according to their mass-to-charge ratio.

Finally, fragment the selected ions and analyze the fragments with a second analyzer.

Detect the ions coming out of the last analyzer and measure their abundance with the detector. The detector converts the ions into electrical signals.

Process the signal from the detector sent to the computer and uses the feedback to control the device.

Analysis of biomolecules using mass spectrometry

Mass spectrometry is becoming an indispensable field for the analysis of biomolecules. Until the 1970s, electrophoresis, chromatography, or ultracentrifugation was the only analytical technique that provided similar information. The results were not absolute as they were based on properties other than molecular weight.

Analysis of glycans

Oligosaccharides are molecules formed by combining multiple monosaccharides.

It is linked via glycosidic bonds. Determining the complete structure of oligosaccharides is more complex than that of proteins and oligonucleotides. It involves determining the isomeric nature of monosaccharides and additional components as a result of their ability to form linear or branched oligosaccharides. In order to know the structure of oligosaccharides, it is necessary to determine not only their monosaccharide sequences and branching patterns, but also the isomer positions and an over arrangements of each glycosidic bond. Advances in glycobiology include extensive studies of carbohydrates and carbohydrate structure, biosynthesis, and biology. Mass Spectrometry (MS) has emerged as an important technology in the fields of glycobiology and glycobiology.

Lipid analysis

Lipids are composed of many classes of various molecules that are soluble in organic solvents. Lipidome, a major part of metabolomics, involves in-depth analysis and global characterization of the structure and function of lipids (lipidomes) in biological systems, both spatially and temporally. Many new strategies have been developed for mass spectrometric-based analysis of lipids. The most common lipidomics methods include Electrospray Ionization (ESI) sources and triple quadruple analyzers. Mass spectrometry can be used to determine the molecular weight, elemental composition, branch location, and substituent properties of the lipid structure.