Dentistry received 2345 citations as per Google Scholar report
        
						Fadi Ismail
	
					    												Clinic of Prosthetic Dentistry and Biomedical Materials Science, Hannover Medical School, 
Hannover
Germany						                            
                            
						
 Research Article
												In Situ Biofilm Formation on Titanium, Gold Alloy and Zirconia Abutment Materials 						
Author(s): Fadi Ismail*,Michael Eisenburger,Sebastian Grade,Meike Stiesch
Fadi Ismail*,Michael Eisenburger,Sebastian Grade,Meike Stiesch
             
						
												
				 Background: Biofilm formation on trans-gingival implant surfaces is a common reason for local inflammation of the peri-implantary tissue and can lead to implant loss. The aim of the current in situ study was to evaluate biofilm formation on titanium, gold alloy and zirconia abutment materials directly in the trans-gingival region.
Materials and Methods: Specimens were attached to implant healing abutments and were inserted in 8 patients for 14 days. Confocal laser scanning microscopy was used to measure biofilm height and surface coverage.
Results: Titanium showed a mean biofilm height of 10.8 μm and a surface coverage of 26.5%. For gold alloy, a height of 14.6 μm and coverage of 27.3% was found. Zirconia had a biofilm height of 2.7 μm and coverage of 10.5%. No statisti.. View More»
				  
												DOI:
												 10.4172/2161-1122.1000400